C&K systems ST800L+ Manual de Instalação Página 4

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 16
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 3
3
SPECIFICATIONS
SPECIFICATION FOR SOFTWARE REVISION NUMBER V3.0
The software revision number is located on the top of the main processor
Power Supply
Mains Supply Voltage 230 V AC Nominal
PSU output voltage 13.7 V Nominal
Maximum output current 1 A (total)
Aux. current 500 mA Max.
Battery Fuse 1 A (20 mm)
Panel Quiescent 40 mA
Keypads
Supply Voltage 13.7 V
Quiescent Current 20 mA
Active 45 mA
Maximum number allowed 6
General
Normal operating temperature 0°C to 40°C
Humidity 10 to 90% R.H. non condensing
Dimensions W 263 mm H 223 mm D 82 mm
Control Panel Weight 2.7 kg Excluding Battery
Standby Battery 7.0 Ah 12 V Rechargeable Lead Acid
Standby Time (load dependant) 24 hrs with 2.8 Ahr nom.
60 hrs with 7.0 Ahr nom.
Based on panel, Keypad, & 2 pir’s
40+20+25+25mA = 110mA Quiescent
Cable Runs
Zone/circuits 100m max with 50mA load.
Sounder 50m max with 7/0.2
100m max with 16/0.2 or 2 x 7/0.2
Factory Defaults
User/customer Code 1 1234
User/customer Code 2 Disabled (0000)
Engineer Code 7890
Circuit 1 Entry Circuit. (Fixed)
Circuit 2 Alarm Circuit isolated in Night set.
Circuit 3 Alarm Circuit.
Circuit 4 Alarm Circuit.
Circuit 5 Alarm Circuit.
Circuit 6 Alarm Circuit.
Circuit 7 Alarm Circuit.
Circuit 8 P.A (Personal Attack)
Full Set Exit Time 30 Seconds
Night set Exit Time 15 Seconds
Entry time 30 Seconds
Sounder Ring Time 15 Minutes
Chimes Disabled
Programmable options Non selected
PROCESSOR
VERSION
POWER
SUPPLY
KEYPADS
GENERAL
FACTORY
DEFAULTS