Resumo do Conteúdo

Página 1 - LED Plus

Part Number 5-051-372-00 Rev BUsing yourLED PluskeypadSystem 2316System 238System 2316iSystem 238i

Página 2 - (Monitoring Station Name)

10Make sure the red ARM light comes on.The keypad will beep twice to confirm that the system is armed.The rest of the ARMING THE SYSTEM section explai

Página 3 - Table of contents

11The keypad will beep twice to confirm that the system is armed.*INSTANT ARMINGInstant Arming converts all time delayed zones to INSTANT zones.CAUTI

Página 4

12HOME ARMINGHome Arming arms perimeter zones, while bypassing interior zones (except24-hour zones).Make sure the green READY light is on.Enter your P

Página 5

13INSTANT HOME ARMINGEnter your PIN (if required),push the key, enter the digit "7",the digit "4", then push the # key.PINREQ

Página 6

14BYPASSING ZONESThis procedure allows you to bypass one or more zones while your system isDISARMED1.NOTE: System programming determines which PINs ca

Página 7

15.To bypass more than one zone: enter yourPIN (if required), push the key, enter thefirst zone to be bypassed, push the keyagain, ent

Página 8

16Your alarm system has been programmed for one of the following three arming types:GOOF-PROOF ARMINGIf any zone other than a 24-hour zone is faulted

Página 9 - Enter your PIN and push the

17CHIRP ALERTThe system will arm even if delay zones are faulted at the time of arming. If azone is still faulted when the EXIT DELAY time expires, t

Página 10 - INSTALLED

18TO DISARM THE SYSTEM:Enter only through a TIME DELAY door.If the ENTRY PRE-ALARM option is installed, the keypad will sound constantly until 10seco

Página 11 - INSTANT ARMING

19AFTER AN ALARM OCCURS:Enter your PIN and push the# key.This will silence the siren/bell and disarm the system..The red ZONE lights on the keypad wil

Página 12 - HOME ARMING

2Thank you for purchasing this C&K alarm system. Your system is one of the most powerfuland advanced alarm systems on the market today, designed

Página 13 - INSTANT HOME ARMING

2024-HOUR MONITORINGWith this option installed, your alarm system will transmit alarm signals toour central station.OPTIONINSTALLEDFIRE KEYWhen this o

Página 14 - BYPASSING ZONES

21POLICE/PANIC KEYWhen this option is installed, holding down the keyfor three seconds will trigger an alarm. The keypad will beeptwice to c

Página 15 - ZONE #ZONE #

22DURESS ALARMShould an intruder force you to turn your security system off or on, you cansend a silent DURESS signal to our central station by enteri

Página 16 - FORCE ARMING

23GUEST COMBINATIONThe SYSTEM 238 can store up to 8 PINs, and the SYSTEM 2316 can store up to 32 PINs.In both systems, PIN #8 can be programmed as a G

Página 17 - CHIRP ALERT

24User 1 can use his Master PIN to change the PINs of Users 1 - 8.CHANGING A SYSTEM 238 AND 238i USER PIN0MASTER PINREQUIRED.#**.##If the new PIN is a

Página 18 - TO DISARM THE SYSTEM:

25Exit the programming mode by pushing the key, then the # key.Make sure the new PIN works.After leaving the programming mode, Arm and Disarm your

Página 19 - AFTER AN ALARM OCCURS:

26DELETING A USER PIN - SYSTEM 238 AND 238iEnter your Master PIN, pushthe key, enter the digit "0", thenpush the ENTER key.MASTER PINREQ

Página 20 - EMERGENCY KEY

27User #1 can use the Master PIN to change the PINs of Users 1 - 32 (See Below).CHANGING A SYSTEM 2316 AND 2316i USER PINNOTE: On System 2316i, User C

Página 21 - DURESS ALARM

28Enter the new PIN again and pushthe # key.#Exit the programming mode by pushing the key, then the # key.Make sure the new PIN works.After leaving

Página 22

29User 1 can use his Master PIN to delete the PINs of Users 2 - 32 (See Note pg. 27).DELETING A USER PIN - SYSTEM 2316 AND 2316iEnter your Master PIN,

Página 23 - RING BACK AFTER CLOSING

3Getting acquainted... 4-5What the lights mean... 6-7What the sounds m

Página 24 - MASTER PIN

30RESETTING SMOKE DETECTORSWhen a smoke detector is triggered, the red ZONE light of the zone where it'slocated will come on, and the bell/siren

Página 25 - Make sure the new PIN works

31DOOR CHIMEWhen this option is installed, the keypad will beep for two seconds each timea designated zone is faulted.OPTIONINSTALLEDTo turn the Door

Página 26

32LOCAL SYSTEM TESTThis option allows on-site testing of each zone in your system.Enter your PIN (if required),push the key, enter the digit "

Página 27 - (See Below)

33STANDBY BATTERY TESTYour alarm system can be programmed to automatically test its standbybattery every 24 hours. During the test, AC power is turn

Página 28

34Enter your PIN (if required),push the key, enter the digit "6",the digit "1", then push the # key.If the test message was su

Página 29 - (See Note pg. 27)

35IF YOU HAVE TELEPHONE TROUBLE:First, unplug the control panel from its telephone jack to determine if thealarm system is causing the trouble.The pho

Página 30 - RESETTING SMOKE DETECTORS

36BED-ROOMBED-ROOMBEDROOMBASEMENTPlace detectors neartop of stairwellsBEDROOM BEDROOM KITCHEN DININGROOMBEDROOM LIVING ROOMBest residential detector p

Página 31 - STANDBY BATTERY

37Every household should establish and regularly practice an escape plan in the event of a fire. The followingsteps, recommended by the National Fire

Página 32 - LOCAL SYSTEM TEST

38ALARMA condition that occurs when the detection devices in a zone aretriggered after the system is armed.EXIT DELAYOnce the system is armed, the tim

Página 33

39THE LIMITATIONS OF YOUR ALARM SYSTEMWhile your alarm system is reliable and sophisticated, it does not offer guaranteed protection against burglar

Página 34 - CENTRAL STATION TEST

4What your alarm system is...Your alarm system is made up of a control panel and several detection devices like motion sensors,magnetic contacts, and

Página 35

As required by UL Standard 1023, your alarm system is a Grade "A" system(see definition on page 38).Alarm system malfunctions and failures a

Página 36

YES NOBYPASSLOCATIONZONE1234567841

Página 37 - SECOND FLOOR

YES NOBYPASSLOCATIONZONE91011121314151642

Página 38

43FCC NOTICEWARNING: This device is intended to be installed by a professional alarm installer. The user shall be cautioned that changes or modifica

Página 39

Printed in Hong Kong5-051-372-00 Rev BC&K is a registered trademark of C&KComponents, Inc.Copyright 1995 C&K SYSTEMS, Inc.All Rights Res

Página 40

5Each alarm system in the 2300 family is designed to meet the specific needs of a variety of applications. Systems238 and 2316 are designed for appli

Página 41

6off on steady Power fail. System on battery.on steady Ready to arm.off on steady One or more zones are faulted.off* o n steady *Ready light will be

Página 42

7slow flash slow flash slow flash System is in programming mode.fast flash Call for service.on steady Call for service. slow flash on steady Call for

Página 43 - FCC NOTICE

8SOUND MEANING2 beeps system armed or disarmed.successful central station test or battery test.5 beepsinvalid functionunauthorized command attempteder

Página 44

9Make sure the green READY light is on.If the READY light is not on, the red ZONE lights will indicate which zone(s) are faulted.Faulted zones must be